Friday, 22 July 2005
A.Farina, L.Tronchin
14
/86
ADC (Analog to Digital Converter) 3
Low-pass filtering must be applied before entering the
ADC, otherwise the signal will be aliased
Example
: pure tone of 35 kHz
Sample rate 48 kHz,
Nyquist freq. 24 kHz,
difference = 11 kHz
After digital conversion will be 13 kHz (i.e. 24-11 kHz)
Solution
: low-pass antialiasing filters, oversampling